KEBERLAKUAN MODEL HB-GFT SISTEM n-HEKSANA – MEK – AIR PADA EKSTRAKSI CAIR-CAIR KOLOM ISIAN

Agus Mirwan

Abstract


Liquid-liquid extraction in packed column is a process of liquid phase separation in which a liquid solution (the feed) is contacted with an immiscible or nearly immiscible liquid (solvent). This type of extraction is a kind of vertical column extraction type without agitator (unagitated column) besides spray column and plate column. Good operation of liquid-liquid extraction hardly influenced by solute transfer characteristic. This characteristic can be quantification with a value so-called with mass transfer coefficient. Mass transfer coefficient is importance in order to be known in scheme of liquid-liquid extraction column and the values can be searched by using estimation models of mass transfer coefficient either in dispersion phase and also continue phase.

The aim of this research is to prove model applying Handloss-Baros - Garner-Foord-Tayeban (HB-GFT) at liquid-liquid extraction process using transparent column prototype and packing type of small sphere with various of flow rate continue phase and dispersion phase at circulation drop spread (Re = 10 - 200). From this research got that packing type, droplet size, and flow rate phase (dispersion and continue) gives influence that is enough significant to mass transfer process that expressed with overall mass transfer coefficient (KOD). Flow rate and composition each phase in inlet and outlet column data are analyzed by using gas chromatography equipment (GC) that showed more and more big dispersion phase (Qd) flow rate, mass transfer coefficient (KOD) more and more small. This caused that drop diameter measure along the length of packing column assumed to be same. And model applying HB-GFT for internal circulation drop dynamics (170<Re<200) is best combination in determination of KOD with deviation standard equal to 3,2%.


Keywords


extraction, packing column, mass transfer

Full Text:

PDF

References


. Arfianti, D., (2004), Koefisien Perpindahan Massa Fasa Kontinyu Ekstraksi Cair-Cair Mek-N-Heksana-Air Dalam Kolom Isian, Tesis Program Magister, Institut Teknologi Bandung.

. Ariono, D., Sasongko, D., Kusumo, P., (2006), Dinamika Tetes Dalam Kolom Isian, Seminar Nasional Teknik Kimia Indonesia, FPUO 14. 1 – 5.

. Ariono, D., Sasongko, D., Purwasasmita, M., Kusumo, P., (2008), Pengaruh Jenis Isian Terhadap Dinamika Tetes Fasa Dispersi Dalam Kolom Isian, Seminar Nasional Rekayasa Kimia & Proses Universitas Diponegoro Semarang, ISSN 1411 – 4216, K.085.

. Ariono, D., Mirwan, A., (2008), Dinamika Tetes dan Koefisien Pindah Massa Pada Ekstraksi Cair-Cair Dalam Kolom Isian, Seminar Nasional Rekayasa Kimia & Proses Universitas Diponegoro Semarang, ISSN 1411 – 4216, A.096.

. Hashem, M. A., El-Bassuoni, A. A., (2007), Drop Formation Mass Transfer Coefficients in Extraction Columns, Theoretical Foundations of Chemical Engineering Journal. Vol. 41, No. 5, 530 – 535.

. Hume, A. P., Weatherley, L. R., Patera, J., (2003), Trajectories of Charged Drops in a Liquid-Liquid System, Chemical Engineering Journal, 95, 171 – 177.

. Kumar, A., Harland, S., (1996), Unified Correlations for Prediction of Drop Size in Liquid-Liquid Extraction Columns, Ind. Eng. Chem. Res., 35, 2682 – 2695.

. Laddha, G.S., Degaleesan, T.E., (1976), Transfort Phenomena in Liquid Extraction, Tata Mc-Graw Hill Publishing Co. Ltd, New Delhi, 131 – 145.

. Mirwan, A., D. R. Wicakso., (2008), Pengaruh Isian Jenis Bola Kaca Terhadap Dinamika Tetes Dan Koefisien Pindah Massa Ekstraksi Cair-Cair Dalam Kolom Isian, Jurnal Info Teknik Fakultas Teknik UNLAM, ISSN 0853-2508 Volume 9 No.2

. Nababan, R. F., (2006), Penerapan Model HB-GFT Proses Ekstraksi Cair-Cair Sistem MEK – Air – n-Heksan Dalam Kolom Isian, Laporan Tugas Akhir Penelitian, Institut Teknologi Bandung.

. Seibert, A. F., Fair, J. R., (1988), Hydrodynamics and Mass Transfer in Spray and Packed Liquid-Liquid Extraction Columns, Ind. Eng. Chem. Res., 27, 470 – 481.

. Treyball, R., (1980), Mass Transfer Operation, 3rd edition, Mc Graw Hill, New York.

. Treyball, R., (1950), Liquid-Liquid Extraction, Mc Graw Hill, New York.

. Verma, R. P., Sharma, M. M., (1975), Mass Transfer in Packed Liquid-Liquid Extraction Columns, Chemical Engineering Science,Vol. 30, pp. 279 – 292.




DOI: http://dx.doi.org/10.20527/infotek.v11i1.1767

DOI (PDF): http://dx.doi.org/10.20527/infotek.v11i1.1767.g1539

Article Metrics

Abstract view : 2593 times
PDF - 3854 times

Refbacks

  • There are currently no refbacks.


Copyright (c) 2016 INFO-TEKNIK

Creative Commons License
This work is licensed under a�Creative Commons Attribution 4.0 International License.�

joomla
statistics View My Stats

Indexed By:

Citation :

SINTA 6 mulai Vol. 19 No. 2 2018 (SK NO. 164/E/KPT/2021)

GOOGLE SCHOLAR : Sitasi = 78, H-index = 5, i10-index = 2

IPI :� Artikel = 100

IOS 3969 : Artikel = 239