UJI KEBOCORAN MIKRO RESIN MODIFIED GLASS IONOMER CEMENT (RMGIC) SEBAGAI BAHAN BASIS PASKA OBTURASI SALURAN AKAR
Abstract
ABSTRACT
Background: : Dental caries is a disease of the hard tissues of the teeth characterized by demineralization and destruction of tooth tissue. This damage begins on the tooth surface and can extend to the pulp. Root canal treatment must have a good fluid tight seal. This is achieved by using a post-root canal obturation base. This base uses resin modified glass ionomer cement because it has good biocompatibility and setting time with dual cure. Purpose: To determine the microleakage of resin modified glass ionomer cement (RMGIC) as a post-root canal obturation base material with a base thickness of 1 mm and 2 mm. Method: This study was a pure experimental study with a post-test-only with control design. This study used 14 mandibular first premolars divided into 2 groups, namely group 1 with a base thickness of 1 mm and group 2 with a base thickness of 2 mm. Results: The average microleakage value on a 1 mm base thickness was 0.0629 and the microleakage value on a 2 mm base thickness was 0.3271. Conclution: The result of the unpaired T-test showed a significant difference in microleakage between the 1 mm base group and the 2 mm base group. The lowest microleakage was on a 1mm base and the highest microleakage was on a 2 mm base.
Keywords: base, microleakage, resin modified glass ionomer cement
ABSTRAK
Latar belakang: Karies gigi adalah penyakit jaringan keras gigi yang ditandai demineralisasi dan kerusakan jaringan gigi. Kerusakan ini dimulai dari permukaan gigi dan dapat meluas ke arah pulpa. Perawatan saluran akar harus mempunyai fluid tight seal yang baik. Hal ini didapatkan dengan melakukan basis paska obturasi saluran akar. Basis ini menggunakan resin modified glass ionomer cement karena memiliki sifat biokompatibel yang baik dan setting time dengan dual cure.Tujuan: Mengetahui kebocoran mikro resin modified glass ionomer cement (RMGIC) sebagai bahan basis paska obturasi saluran akar dengan ketebalan basis 1 mm dan 2 mm. Metode: Penelitian ini merupakan eksperimental murni dengan rancangan post test-only with control design. Penelitian ini menggunakan 14 gigi premolar pertama rahang bawah dibagi menjadi 2 kelompok yaitu kelompok 1 dengan ketebalan basis 1 mm dan kelompok 2 dengan ketebalan basis 2 mm. Hasil: Rata rata nilai kebocoran mikro pada basis ketebalan 1 mm adalah 0,0629 dan nilai kebocoran mikro pada basis dengan ketebalan 2 mm adalah 0,3271. Kesimpulan: Hasil uji T-test tidak berpasangan menunjukkan perbedaan kebocoran mikro yang bermakna antara kelompok basis dengan ketebalan 1mm dan kelompok basis dengan ketebalan 2 mm. Kebocoran mikro paling rendah pada basis 1mm dan kebocoran mikro paling tinggi pada basis 2 mm.
Kata kunci : basis, kebocoran mikro, resin modified glass ionomer cementFull Text:
PDFReferences
Haikal M, Adhani R, Wardani IK. Hubungan Laju Aliran Saliva terhadap Kejadian Karies Gigi pada Penderita Hipertensi yang Mengkonsumsi Obat Antihipertensi. Jurnal Kedokteran Gigi. 2020;4(2):39-42.
Listrianah. Indeks Karies Gigi Diinjau dari Penyakit Umum dan Sekresi Saliva pada Anak di Sekolah Dasar Negeri 30 Palembang. Jurnal Kesehatan Palembang. 2017;12(2):136-148.
Syakirah T, Deynilisa S. Gambaran Angka Kunjungan Pasien Nekrose Pulpa di Puskesmas Padang Selasa Tahun 2019. Jurnal Kesehatan Gigi dan Mulut. 2020;2(1):29-33.
Bachtiar ZA. Perawatan Saluran Akar pada Gigi Permanen Anak dengan Bahan Gutta Percha. Jurnal PDGI. 2016;65(2):60-67.
Hajir R, Iswani R, Widyanti. Perbedaan Radiopasitas antara Bahan Obturasi Sealer Berbahan Dasar Kalsium Hidroksida dan Epoksi Resin dengan Teknik Radiografi Cone Beam Computed Tomografhi (CBCT). Jurnal B-Dent. 2018;5(1):49-55.
Sundari I, Ningsih DS, Putri CF. Perbandingan Kebocoran Mikro Basis GIC Convensional dan RMGIC pada Restorasi Resin Komposit Nanofiller dengan Teknik Sandwich. Cakradonya Dent Journal. 2013;5(2):610-618.
Wajong KH, Damiyanti M, Irawan B. The effects of shelf life on the compressive strength of resin-modified glass ionomer cement. Journal of Physics Conf Ser. 2017;884(1):1-6.
Arba KF, Fatmawati DWA, Lestari S. Effect of Horizontal Tooth Brushing Methods to The Surface Roughness of NCR, GIC, and RMGIC in Class V Cavities. Journal Of Indonesial Dental Association. 2021; 4(1):35-40.
Alkhudhairy F. Dentin conditioning using different laser prototypes (Er, Cr:YSGG; Er:YAG) on bond assessment of resinmodified glass ionomer cement. Journal Contemp Dent Pract. 2020;21(4):426-430.
Korkut E,Gezgin O, Tulumbaca F, Ozer H, Sener Y. Comparative Evaluation of Mechanical Properties of a Bioactive Resin Modified Glass Ionomer Cement. EU Dishek Fak Derg. 2017;38(3):170-175.
Ayudia TK, Putri KS, Fitria I. Perbandingan Kebocoran Mikro pada Restorasi Resin Komposit Mikrofiler dengan Resin Modified Glass Ionomer Cement (RMGIC) pada Kavitas Klas V Gigi Anterior. Andalas Dental Journal; 2015: 3(2). 76-84.
Sofiani E, Rovi F. Pengaruh Lama Penyinaran dan Ketebalan Resin Komposit Bulk Fill terhadap Kebocoran Mikro. Insisiva Dental Journal; 2020: 9(2).72-81.
Permana DP, Sujatmiko B, Yulianti R. Perbandingan Tingkat Kebocoran Mikro Resin Komposit Bulk-Fill dengan Teknik Penumpatan Oblique Incremental dan Bulk. Majalah Kedokteran Gigi Indonesia; 2016: 2(3). 135-140.
ningsihHalim EN, Samadi K, Kunarti S. Efek Antibiofilm Glass Ionomer Cements dan Resin Modified Glass Ionomer Cements terhadap Lactobacillus acidophilus. Conserv Dent J. 2019; 7(2): 120-129.
Chandak MS, Chandak M, Nikhade PP, Rathi CK, Khatod SS, Rathi SD. Role of Liners in Restorstive Dentistry. Journal Evolution Med.Dent.Sci. 2020;9 (25):1881-1886.
DOI: https://doi.org/10.20527/dentin.v9i2.17738
Refbacks
- There are currently no refbacks.
Contact Us:
Faculty of Dentistry
Lambung Mangkurat University
Jalan Veteran No. 128 B Banjarmasin, Indonesia
E-mail. [email protected]
Website. fkg.ulm.ac.id

.png)