Simulasi Pembebanan Gaya Angin pada Baliho Berdasarkan Kode Pembebanan Peraturan Muatan Indonesia dan British Standard BS6399

Arie Febry Fardheny

Abstract


This simulation show 2 major problems, first about wind force in Indonesia loading code, 1970 which is older and no revision. Second, about signboard design for wind force in Indonesia loading code and British loading code, which is British code using envirotment, location and  elevation for wind force. Model Simulation are one leg signboard (baliho type) and two leg signboard. This simulation using finite element software. Result show a lower wind force than British code, which might to consider a revision for Indonesia wind force code. Another result show that deflection in one leg signboard is large if there always a maximum than code . This is a reason why two leg is now use in Banjarmasin. 


Keywords


Simulation – Wind Load - SignBoard

Full Text:

PDF

References


British Standard BS6399 Loading for buildings Part 2, Code of practice for wind loads, 1997

Radar Banjarmasin, Kerusakan Baliho, 22 Mei 2007

Standar Nasional Indonesia, Peraturan Pembebanan Untuk Gedung (PPUG) 1970 disadur dari Sunggono, Buku Teknik Sipil, Nova, 1995, Jakarta

Sap2000, Linier and Non Linier Analysis Introduction, Berkeley , 2005

Sap2000, LRFD 1993 for Steel Analysis, Berkeley, 2005




DOI: http://dx.doi.org/10.20527/infotek.v8i2.1729