PUSHOVER ANALYSIS ON A MOSQUE BUILDING STRUCTURE WITH A TIERED ROOF SLAB
Abstract
Damage to building structures poses a threat to the quality of the building, which will impact its functionality. Structural damage can be caused by earthquakes. This research aims to determine the performance level and the effect of variations in short column heights on the inter-story drift of a mosque building with a tiered roof slab in a pushover analysis. The pushover analysis in this study refers to FEMA 356 and ATC-40, by determining the target displacement value, drift ratio, collapse mechanism, and building performance level. In accordance with FEMA 356, the pushover analysis results show an Operational performance level with drift ratios in the X and Y directions of 0.451% and 0.458% respectively, which means the building only experienced minor damage and can still be used as normal. Based on ATC-40, the analysis results show an Immediate Occupancy performance with a drift ratio in the X and Y directions of 0.00368, so the building is in a safe condition and can be used immediately. The influence of variations in column height on inter-story drift shows that the higher the column, the larger the inter-story drift.
Keywords : Pushover Analysis, Target Displacement, Drift Ratio, Plastic Hinge, Performance Level, Tiered Roof Slab
Full Text:
PDFReferences
ATC-40, 1996. Seismic Evaluation and Retrofit of Concrete Buildings. Redwood City, CA: Applied Technology Council.
ACI, 2019. 318-19 Building Code Requirements for Structural Concrete and Commentary.
Badan Standardisasi Nasional, 2020a. SNI 1726:2019 Tata cara perencanaan ketahanan gempa untuk struktur bangunan gedung dan nongedung. 8.
Badan Standardisasi Nasional, 2020b. SNI 1727:2020 Beban desain minimum dan Kriteria terkait untuk bangunan gedung dan struktur lain. In Jakarta (Issue 8).
FEMA 356, 2000. Prestandard and Commentary for the Seismic Rehabilitation of Buildings. Washington, DC.
Mamesah, H. Y., 2014. Analisis Pushover Pada Bangunan. 2(4), 214–224.
Saputra, R., 2020. Studi Kinerja Gedung Empat Tingkat Terhadap Beban Gempa dengan Metode Statik Pushover. 8(1), 113–124.
Siajaya, K., 2018. Respons Struktur Gedung Bertingkat Dengan Variasi Kekakuan Kolom Akibat Gempa Berdasarkan SNI 03-1726-2012. Jurnal Sipil Statik, 6(6), 411–422.
DOI: https://doi.org/10.20527/crc.v10i4.18925
Refbacks
- There are currently no refbacks.
Copyright (c) 2026 Naek Rizki Pandiangan, Ade Yuniati Pratiwi

This work is licensed under a Creative Commons Attribution 4.0 International License.
Indexed By:
GOOGLE SCHOLAR : Kutipan = 2, H-index = 1, i10-index = 0