DESCRIPTIVE STUDY OF RADIATION DOSE IN CBCT FOR DENTAL APPLICATION
Abstract
Background: Cone Beam Computed Tomography (CBCT) provides superior 3D imaging for dental diagnosis but involves higher radiation exposure than conventional radiography. Therefore, dose optimization based on the ALARA principle and the establishment of Diagnostic Reference Levels (DRLs) are essential for patient safety and radiation protection. Purpose: This study evaluated CBCT exposure parameters and radiation dose variation by FOV to support dose optimization and DRL development. Methods: This retrospective descriptive study analyzed CBCT records of adult patients (September 2023–2024). Variables included tube voltage, tube current, exposure time, voxel size, DAP, Effective Dose, and FOV. Data were analyzed using descriptive statistics and FOV-based comparisons with SPSS version 30. Results: A total of 50 patients were included (56% female and 44% male) had average exposure parameters of 89.80 kV, 2.87 mA, 15 seconds, and 0.148 mm voxel size. The 8x5 cm FOV (4 patients) produced a DAP of 721.50 µGy cm² and an Effective Dose of 70 µSv. The 8x9 cm FOV (46 patients) produced a DAP of 1151.48 µGy cm² and an Effective Dose of 72 µSv. The typical dose value (Q2 DAP) was 1179 µGy cm². Conclusion: Radiation doses in dental CBCT examinations vary depending on the FOV size, with larger FOVs resulting in higher radiation exposure. Selecting the appropriate FOV based on clinical indications, along with dose monitoring and establishing Diagnostic Reference Levels (DRLs), is crucial for optimizing patient safety and radiation protection in dental radiology.
Keywords: Cone Beam Computed Tomography, DRL, Patient Safety, Radiation Protection, TDV
Full Text:
PDFReferences
Mah E, Ritenour ER, Yao H. A Review of Dental Cone-Beam CT Dose Conversion Coefficients. Vol. 50, Dentomaxillofacial Radiology. British Institute of Radiology; 2020.
Kanneppady SS, Kanneppady SK, Mathew T, Almazrou YM, Syed AK, Hota S, et al. Diagnostic Accuracy of Cone-Beam Computed Tomography (CBCT) in Identifying Periapical Lesions: A Comparative Study with Conventional Radiography. J Pharm Bioallied Sci. 2025 May;17(Suppl 1):S476–8.
Gameraddin M, Alessa AA, Aloufi HS, Alzaidi SD, Gareeballah A, Alsaedy HI, et al. Dental radiography and safety awareness: Insights from radiographers, dentists, and students in a cross-sectional study. PLoS One. 2025 Mar 1;20(3 March).
Distefano S, Cannarozzo MG, Spagnuolo G, Bucci MB, Lo Giudice R. The “Dedicated” C.B.C.T. in Dentistry. Int J Environ Res Public Health. 2023 Jun 1;20(11).
Deniz Y, Eren H, Sessiz R, Coşan Ata G. Comparison of CBCT radiation doses with conventional radiographs in TMJ imaging using Monte Carlo simulations. Radiat Environ Biophys. 2024 Mar 1;63(1):39–45.
Shatskiy I. Effective Doses And Radiation Risks From Common Dental Radiographic, Panoramic And CBCT Examinations. Radiat Prot Dosimetry. 2021 Oct 1;195(3–4):296–305.
Elmorabit N, Azougagh M, Marrakchi A, Ennibi OK. Radiation protection in dentistry: a systematic review of knowledge, attitudes, and practices (KAP) and clinical recommendations. Vol. 56, Egyptian Journal of Radiology and Nuclear Medicine. Springer Nature; 2025.
Jasieniak J, Kuchcińska A, Podgórska J, Cieszanowski A. Summary of radiation dose management and optimization: comparison of radiation protection measures between Poland and other countries. Vol. 88, Polish Journal of Radiology. Termedia Publishing House Ltd.; 2023. p. 12–21.
Ahmed NA. Typical Effective Dose Values From Diagnostic And Interventional Radiology. Applied Radiation and Isotopes. 2023 Feb 1;192.
Damilakis J, Frija G, Brkljacic B, Vano E, Loose R, Paulo G, et al. How to establish and use local diagnostic reference levels: an ESR EuroSafe Imaging expert statement. Insights Imaging. 2023 Dec 1;14(1).
Rao S, Sharan K, Sukumar S, Chandraguthi SG, Nisha Dsouza R, David LR, et al. Systematic Review on Diagnostic Reference Levels for Computed Tomography Examinations in Radiation Therapy Planning. Vol. 13, Diagnostics. Multidisciplinary Digital Publishing Institute (MDPI); 2023.
Kepala Badan Pengawas Tenaga Nuklir. Kepala Badan Pengawas Tenaga Nuklir Republik Indonesia. 1211/K/V/2021 Indonesia; May 24, 2021.
Badan Pengawas Tenaga Nuklir. Pedoman Teknis Penerapan Tingkat Panduan Diagnostik Indonesia (Indonesian Diagnostic Reference Level). Jakarta; 2021.
Hwang J, Yoon HM, Hwang JY, Choi YH, Lee YY, Lee SM, et al. Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea. Korean J Radiol. 2025 Jan 1;26(1):65–74.
Amalia T, Zulkarnaien B, Anam C, Nurcahyo K, Tussyadiah H, Pradana DE. The Establishment of Institutional Diagnostic Reference Levels (DRLs) in the Cipto Mangunkusumo Hospital. Atom Indonesia. 2022 Aug 1;48(2):159–67.
Khafaji M, Barnawi R, Amoudi S, Gabbani H, Alhazmi R, Ahyad R, et al. Diagnostic reference levels for common pediatric computed tomography studies: A retrospective study. Radiation Physics and Chemistry. 2024 Feb 1;215.
Abuzaid MM, Elshami W, Jayachandran D, Korappil N, Tekin HO. Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates. Tomography. 2022 Dec 1;8(6):2939–45.
Kang J, Won J, Gil J, Min Y, Heo MS. Establishment of Diagnostic Reference Levels for Dental Radiography in 2023. Public Health Weekly Report. 2024 Aug 22;17(33):1393–405.
Pauwels R. A New Formula For Converting Dose-Area Product to Effective Dose in Dental Cone-Beam Computed Tomography. Physica Medica. 2023 Aug 1;112.
Brasil DM, Merken K, Binst J, Bosmans H, Haiter-Neto F, Jacobs R. Monitoring cone-beam CT radiation dose levels in a University Hospital. Dentomaxillofacial Radiology. 2023 Feb 1;52(3).
Dawood E, Ashmawy M, Ahmed N. Impact of field of view on Cone Beam Computed Tomography voxel density value: A Systematic review. Egypt Dent J. 2024 Jan 1;70(1):209–19.
DOI: http://dx.doi.org/10.20527/dentino.v11i1.26067
DOI (PDF): http://dx.doi.org/10.20527/dentino.v11i1.26067.g12137
Article Metrics
Abstract view : 171 timesPDF - 96 times
Refbacks
- There are currently no refbacks.
Contact Us:
Faculty of Dentistry
Lambung Mangkurat University
Jalan Veteran No. 128 B Banjarmasin, Indonesia
E-mail. [email protected]
Website. fkg.ulm.ac.id

This work is licensed under a Creative Commons Attribution 4.0 International License.


.png)